I’ve got two mini-split units (ducted 2nd floor and ductless 1st floor), both installed on the interior of the house. The refrigerant lines are to be routed down through interior walls to the basement, then out through the rim joist to the exterior units. The condensate lines will be gravity drained through the walls as well, but I’m trying to decide where to take them once they get to the basement — I can’t go out the rim joist with the refrigerant lines because it wouldn’t be sloped properly (and I’ve never liked just dribbling it out the side of the house either). The options are:
1: There is a sanitary sewer line running alone one basement wall, on the same side of the house as the mini-splits and where the refrigerant lines will be run. There is a 2″ line that comes out of that for a secondary sink in the kitchen that is conveniently located. I could tap into that, add a trap and an air gap, and drain the condensate lines here. The two potential issues are (1) the trap could be at risk of drying out in the winter, and might need a trap primer, and (2) plumbing code vent rules are tricky to understand but I think technically I’d need to install an AAV to vent the trap — even though the trap itself would be near the ceiling and the only other thing on that sewer branch is a sink on the floor directly above. Seems like a lot of complexity for a dribble of condensate!
2: Run the condensate lines to the middle of the basement, down along the wall in the middle, then around and into a utility sink in the corner of the basement (that subsequently drains into a floor drain). This is running condensate line quite a bit further, but eliminates all the extra trap / air gap / vent stuff.
3: Run condensate lines down to the floor, around the edge of the walls, and then across the floor to a floor drain in the middle of the room. This is basically what HVAC people around here do with standard A/C condensate lines, but I kind of hate it — especially since I might at some point insulate / finish the basement walls, and I don’t like tripping over pipes running across the middle of the floor either.
GBA Detail Library
A collection of one thousand construction details organized by climate and house part
Search and download construction details