Expert Member BILL WICHERS | | #1
I would put a poly vapor barrier up, and wrap it under the sill plate too. Inspectors might want a treated sill though regardless.
Bill
-
kickstarter | | #2
Thanks. You’re so helpful, seriously.
So I can use say a 6mil poly vapor barrier against the concrete and just use regular, non pressure treated 2x4s directly into the concrete? For reference, I have 6 mil visqueen underneath the concrete slab.
-
Expert Member BILL WICHERS | | #3
Against the wall yes, on the floor, inspectors might still want a treated sill, even though it’s not really necassary with a capillary break (poly sheet) wrapped underneath.
Bill
-
Expert Member MALCOLM TAYLOR | | #4
kickstarter,
An alternative to using pt wood where it is contact with concrete or masonry, is to use a sill seal between the two.
IRC R-317.1