Expert Member MALCOLM TAYLOR | | #1
Billy,
You can, but it presupposes your stem-walls and the framing above are going to align very closely. If I were doing it I’d have a drip-flashing, and whatever material you are planning to use as a covering for the mineral wool stopping at the top of the stem-wall – which would also provide a barrier against infestations moving upwards. You can still use a foot of mineral wool above that before starting the foam.
-
GBA Editor RANDY WILLIAMS | | #2
As Malcolm said, it can be done that way. This is from a project we worked on a couple years ago. The wall insulation planed out with the foundation insulation. 3-in on the foundation, 2 1/2-in. on the wall plus the 1/2-in osb. We added the drip cap even though everything was in the same plane.
-